"AIP desktop safety tester test items mainly include ac hi-pot, dc hi-pot, insulation resistance, grounding resistance, leakage current, load power, low voltage startopen short circuit test."

AIP desktop safety tester is used in household/commercial electrical appliances, motors, water pumps, fans, lamps, power tools, heat pumps, photovoltaic energy, electronic power and other industries.

2-产品
Products

Desktop safety tester

Desktop safety tester is equipped with a 10.4-inch full-color touch screen as standard, with a touch keyboard for quick input. Using self-developed software, it has modular functions such as data collection, storage, analysis, and transmission, which can realize information interconnection and meet the requirements of intelligent safety testing in an all-round way.

The tester is used in household/commercial appliances, motors, water pumps, fans, lamps, electric tools, heat pumps, photovoltaic energy, electronic power and other industries.

Key Features

Touch keyboard: This product comes with a 10.4-inch full-color touch screen and a touch keyboard for quick settings.

Modularization: The functions of each module of the tester adopt a customized board design.

Remote upgrade: The tester software can be remotely upgraded to the latest customized version to solve problems of the software and meet customer needs.

Barcode scanning: The tester is equipped with a code scanner, which can scan the barcode group, and the barcode is interconnected with the test data, which is convenient for data management and analysis.

Wireless network: The tester can connect to wireless network and mobile phone hotspot to realize networking functions such as network information transmission, remote diagnosis, and remote upgrade.

Data storage: The tester has the functions of local data storage and networking to realize data management, analysis, uploading, etc. Its USB interface can realize data import and export and interface with information systems such as MES.

Anti-high voltage: The tester can monitor the circuit in real time and automatically sense the state of the measured object. For example, if someone touches the high-voltage circuit, the tester will automatically disconnect the high-voltage output to ensure the safety of the operator. 

Rich interfaces: The tester comes with USB, LAN, RS232 and other interfaces, and supports TCP/IP network protocol, PLC simulation technology, CAN communication and other functions. Its built-in WIFI facilitates the control and expansion of the instrument.

Technology

Parallel testing: The tester can test surge and grounding items at the same time, which improves the test efficiency.

Diagnosis of faults: The tester can be operated remotely, quickly find and resolve tester faults.


Anti-high voltage: The tester can monitor the circuit in real time and automatically sense the state of the measured object. For example, if someone touches the high-voltage circuit, the tester will automatically disconnect the high-voltage output to ensure the safety of the operator. It can also be connected to the MES system, and the test data is automatically uploaded to the client server.

Specification

AC Hi-pot

Rated Output

5000V/40mA(optional 100mA,≤4000V/150mA)

Output voltage range/precision

100~5000V ±(1%×setting value+2 words)

Current test range/precision

0.000~150.000mA  ±(1%×reading value+5 words)

Arc detection

1 ~ 9 (9 is the most sensitive) 0 means turn off the arc function

DC Hi-pot

Rated Output

6000V/10000uA

Output voltage setting range/precision

100~6000V ±(1%×setting value+2V)

Breakdown current test range/precision

0.0~10000uA(optional 25000μA)  ±(1%×reading value+5 words)

Insulation resistance

Rated output

6000V /50GΩ

Output voltage range/precision

100~6000V  ±(1%×reading value+2V)

Resistance test range

1.000MΩ~50.00GΩ

Resistance test resolution

0.001MΩ   0.01MΩ  0.1MΩ  1MΩ   0.01GΩ

Test precision

1.000MΩ~999.9MΩ   output 200~500V

±(7%×reading value+3 words)


1.000MΩ~999.9MΩ   output 501~6000V

±(5%×reading value+3 words)


1.00GΩ~10.00GΩ     output 501~6000V

±(7%×reading value+3 words)


10.00GΩ~50.00GΩ    output 1000~6000V

±(15%×reading value+3 words)

Grounding resistance

Rated output

40A/600mΩ(optional 64A)

Output current Range/precision

AC 5.0~40.0A  ±(1%×setting value+5words) 

Grounding resistance range/precision

1.0~600mΩ  ±(1%×display value+5 words)

Voltage test resolution/precision

0.01V  ±(1%×reading value+3 words)

Leakage current

Set leak type/body network (MD card)

Dynamic leakage, static leakage Standard network GB/T12113 Figure 4 Any human body network can be customized.

Output voltage setting range/precision

0.0V~300.0V  ±(0.4%×setting value+0.1%×range)

Leakage current test range

0.000~20.000mA

Leakage current test precision

DC

±(1%×reading value+0.02mA)


15Hz≤f≤100kHz

±(1%×reading value+0.02mA)


101kHz≤f≤1000kHz

±(2%×reading value)  (>10uA)

Load power

Output voltage setting range/precision

0.0~300.0V  ±(0.1%×reading value+0.1%×range)

Power test range/resolution

0.0~999.9W 1000~6000W  0.1W 1W

Power test precision

 

PF>0.9

±(0.1%×reading value+0.1%×range)


PF≤0.9

±(0.4%×reading value+0.1%×range)

Low voltage start

Output voltage setting range/precision

0.0~300.0V  ±(0.1%×reading value+0.1%×range)

Starting current test range/precision

0.000~9.999A  10.00~20.00A  ±(0.1%×reading value+0.1%×range)

Open short circuit test

Test voltage

10VDC

Resistance test range/precision

2.0~999.9Ω  ±(5%×reading value+5 words)


FAQ
  • What is a desktop safety compliance tester?

    The safety regulation tester is a specialized instrument used for the withstand voltage measurement test of high-voltage elements and devices, mainly to detect whether the product is leaking electricity, whether it is well grounded, and whether it will harm personal safety.

  • What are the testing items of a desktop safety tester?

    The main testing items include voltage, leakage current, insulation resistance, and grounding resistance.

  • What is Flashover Electrical Flashover (ARC)?

    The safety standards clearly state that there must be no insulation breakdown, while some safety standards require that there must be no electrical flashover/ARC, but there is no absolute testing standard. ARC is a type of electrical discharge that indicates insufficient insulation capacity when it occurs. If multiple occurrences of ARC occur, it can lead to insulation damage.

  • How many types of insulation are there in safety regulations?

    There are four types of insulation: Basic, Supplementary, Double, and Reinforced. Due to the possibility of surface discharge caused by excessive dust, humidity, or other reasons inside the product, it is also necessary to use voltage withstand testing to determine whether there are issues with surface distance or insufficient insulation in the internal circuit design of the product.

  • What is a voltage withstand test?

    Voltage withstand test is one of the most common safety regulations tests, and the common terms' dielectric with stand ',' high potential ', and' hit test 'all refer to voltage withstand test. The main purpose of voltage withstand test is to test the insulation capacity of DUT (Device under Test).