One test station works normal and the other one shows fault.

please check the wire connection first, to see if there is any loose connection on the abnormal side.If all wire connection are confirmed ok, please exchange B10A PCB of left and right side.

Technical Support

One test station works normal and the other one shows fault

When it comes that one test station works ok and the other one not, please check the wire connection first, to see if there is any loose connection on the abnormal side.


           


If all wire connection are confirmed ok, please exchange B10A PCB of left and right side, then check if the problem switches together with the B10A PCB, if yes, please change the B10A with spares.